Field wiring diagrams

Note:

Field wiring diagrams are intended to aid electricians or technicians in understanding how equipment
works. All field wiring must be installed in accordance with all local and NEC codes.

Connecting beverage lines

1. Connect syrup and water lines. Non-carbonated water line will be labeled “water”. Syrup lines are numbered

and correspond to the valves as shown in drawing(s) below. Valve one is always next to ice tower.

2. The center 4 valves are pre-plumbed to both carbonated and non-carbonated water lines with the

QuickCARB

beverage manifold. Valves can be individually changed from carbonated to non-carbonated

flavor with the flip of a lever (see below).

3. Clean and sanitize beverage lines in accordance with cleaning instructions.

LEGEND

WIRENUT FIELD
CONNECTIONS

X

EQUIPMENT
GROUND

B

W

GRN

BL

Y

DISPENSER

If attaching
optional icemaker
accessory

LEFT JUNCTION BOX

RIGHT JUNCTION BOX

BL

Y

RD

W

B

LOWER JUNCTION BOX

ICEMAKER #2
(OPTIONAL)

W

B

X

GND

GRN

B

W

LOWER JUNCTION BOX

ICEMAKER #1
(OPTIONAL)

UPPER JUNCTION BOX

BLACK
WHITE

GREEN

BLUE
YELLOW

RD

RED

ELECTRIC
POWER
SOURCE

X

GND

GRN

B

W

UPPER JUNCTION BOX

ELECTRIC
POWER
SOURCE

Electric
Power
Source

GND

GRN

B

W

Valve position #1 is always next to ice

tower. Left hand unit shown.

10 9

8

7

6

5

4 3

2 1

carbonated

non-carbonated

VU300B QuickCARB manifold

(see dispenser for model specific

QuickCARB configuration)