Specifications, Electrical, Plumbing – Follett 00119628R01 User Manual
Page 5
5
Specifications
Electrical
Each dispenser requires a separate circuit with electrical disconnect within 10 ft (6m). Equipment ground
required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 20 amps, Maximum icemaker
fuse – 20 amps each. Cord and plug provided with each dispenser.
Icemaker
Dispenser
amperage
amperage
VU300K series
11.0 amps ea (2)
11.5 amps
Plumbing
Dispenser
3/4" PVC pipe nipple for bin drain
3/4" PVC pipe nipple for drain pan drain
1" ID hose for beverage bath drain
Beverage connections
1/4" ID syrup beverage hose
3/8" 45° flair fitting for carbonated water inlet
1/4" ID CO
2
3/8" ID plain water inlet
Note:
Set CO
2
pressure to 75 psi and syrup pressure to 60 psi.
Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)
slope on drain line run.
Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Follett recommends use of a Follett model AFSYSTMFL4S water filter on icemakers connected
to automatic fill dispensers.
Icemaker
Refer to detailed specifications in icemaker installation manual
packed with icemaker