3-4

SIG DET S LEVEL

SIG DET S LEVEL judges whether the DSC frequency to use to send a DSC message
(Routine only) is in use or not. The DSC message is not transmitted when the signal
strength on the DSC frequency is higher than that set here. When the DSC frequency
becomes clear, the DSC message is automatically transmitted. The setting range is OFF
–255 and the default setting is 100.

1. Rotate the [ENTER] knob to select “SIG DET S LEVEL”.
2. Press the [ENTER] knob to display the S LEVEL pop-up window.

S LEVEL (OFF 255)

SIG DET S LEVEL pop-up window

3. Rotate the [ENTER] knob to adjust the indicator bar. Too low a setting stops

transmission of a DSC message because it detects noise on the DSC frequency.
Alternately, too high a setting transmits the DSC message though low signal level is
present on the DSC frequency used.

4. Press the [ENTER] knob to finish.

REGULATION

Set the regulation to be used.

1. Rotate the [ENTER] knob to select “REGULATION”.
2. Press the [ENTER] knob.

INTL

RUSSIA

Regulation pop-up window

3. Rotate the [ENTER] knob to select “INTL” or “RUSSIA”. Only for Russia registry, select

“RUSSIA”.

4. Press the [ENTER] knob to finish.

DIST

Shows the last transmitted DISTRESS information.