3 connection of ac-dc power supply unit (option) – Furuno FS-2570 User Manual
Page 31

2-9
2.3
Connection of AC-DC Power Supply Unit
(option)
When connecting to an AC and DC ship’s mains, the optional AC-DC power supply unit
PR-300 (FS-1570) or PR-850A (FS-2570) is required. Attach the crimp-on lug FV5.5-S4
(local supply) to the power cable (local supply) for connection with the power supply unit.
Use the power cable having the specifications shown in the illustration below.
•
Between PR-300 and FS-1570
DPYC-6 (Japan Industrial Standard) or equivalent
•
Between PR-850A and FS-2570
DPYC-10 (Japan Industrial Standard) or equivalent
Sheath
Conductor
Armor
Tape
Paint
S = 6.0 mm
=3.12 mm
2
(DPYC-6)
S = 10.0 mm
=4.05 mm
2
(DPYC-10)
DPYC, sectional view