1.3 Operator panel

The operator panel is located on the right side of the

scanner. The panel consists of a Function Number Dis-

play, four buttons and a LED.

.

*) About the settings on the launcher, refer to FUJITSU

TWAIN32 scanner driver help and "fi-5530C2 Oper-
ator’s Guide" on the Setup CD-ROM.

Indications on the Function

Number Display

The following shows the indications on the Function
Number Display.

Name

Function

Function Number
Display

Indicates the state of the scan-
ner. The meaning of the num-

bers and alphabets indicated

are explained later in this sec-
tion.

Buttons

Function

Changes the Function activated
by the [Send to] button (*).

Send to

Launches the linked applica-
tion software (*).

Scan

Power button

Turns the scanner ON and

OFF.

LED

-

Lights when the scanner is

turned ON.

Function No.
display

Function

Send to

Scan

LED

Power button

Indication

Meaning

8

Lights only one time upon turning on the

scanner.

P

Indicates that the scanner has been turned

ON and is being initialized.

0

Indicates that initialization will soon be
completed.

1

Indicates that initialization has been com-

pleted successfully.
This status is called "Ready Status."

U

Indicates that a temporary error (that users

can solve) has occurred during the initial-
ization or scanning of documents.

[U] and an error number (1, 2, 6) are dis-
played alternately.

To return the scanner to the ready status

([1]), press the [Scan] or [Send to] button
while the error is indicated.

E

Indicates that a device alarm (that users can

not solve) has occurred during the initial-
ization or scanning of documents.

[E] and an alarm number (2 to 9, and, c, d,

F) are indicated alternately.
To return the scanner to the ready status

([1]), press the [Scan] or [Send to] button.

If this alarm occurs, turn the power off and
then on again. If the alarm is indicated after

turning on the power again, contact your

servic engineer.