4.3.3

Cable connector requirements

Table 4.3 lists the recommended components cable connection.

Table 4.3

Recommended components for connection

Applicable

model

Name

Par number

Manufacturer

Reference

(Figures 4.23

and 4.28)

MAx3xxxSP

SCSI cable (CN1)

Cable socket
(closed-end type)

786090-7

AMP

S1

Signal cable

Power supply cable
(CN1)

Cable socket
housing

1-480424-0

AMP

S2

Contact

60619-4

Cable

60617-4

External operator
panel (CN1)

Cable socket
housing

FCN-723J012/2M

Fujitsu Limited

S3

Contact

FCN-723J-G/AM

Fujitsu Limited

Cable

AWG26 to 34

External operator
panel (CN7)

Cable socket
housing

FCN-723J016/2M

Fujitsu Limited

S4

Contact

FCN-723J-G/AM

Fujitsu Limited

Cable

AWG28

MAx3xxxSC SCSI connector

(CN1)

Connector

787311-1

AMP

(1)

SCSI cable

All SCSI devices on one bus are daisy-chained with an SCSI cable. A terminating resistor
must be mounted in the SCSI device at each end of the SCSI cable.

Because an SCSI terminating resistor module has been mounted in the IDD of single-ended
type SCSI at factory shipment, it must be set to not-connection when the IDD is not connected
at either end of the SCSI cable. See Section 5.3 for details.

The maximum number of SCSI devices that can be connected to the SCSI bus is 16 for the 16-
bit SCSI, including the host adapter, IDD, and other SCSI equipment.

For the 16-bit SCSI, the connector for the SCSI cable must be an unshielded 68-contact socket
having 34-contact rows spaced 1.27 mm (0.05 inch) apart. (See Figure 4.26.)