Frymaster FOOTPRINT 8196345 User Manual
Page 72
2-18
2.8
Gas Supply and Combustion System Components cont.
ITEM PART
#
COMPONENT
1
Ignitor (includes gasket 816-0059, which may be ordered separately)
826-0981
Natural Gas (G20, G25)
826-0982
Propane (G30, G31)
826-1002
Manufactured
Gas
2
Blower Assembly, Combustion Air (includes harness and Items 4, and 5)
106-2996SP
100V 50/60 Hz (Left)
106-2999SP
100V 50/60 Hz (Right)
106-2994SP
115V 50/60 Hz. (Left)
106-2997SP
115V 50/60 Hz (Right)
106-2995SP
208-240V 50/60 Hz (Left)
106-2998SP
208-240V 50/60 Hz (Right)
106-3000SP
230V 50/60 Hz CE (Left)
106-3001SP
230V 50/60 Hz CE (Right)
3
816-0554
Cover, Blower Motor (component of all blowers listed above)
*
806-8806SP
Harness Assembly, Blower Motor (component of all blowers listed above)
4
Orifice,
Burner
812-1137
1.95 mm Propane/Butane (G30, G31) (0-4999 Ft, 0-1524 M) (CE)
810-1221
2.00 mm Propane/Butane (0-4999 Ft, 0-1524 M) (Japan only)
810-0386
2.10 mm Propane/Butane (0-4999 Ft, 0-1524 M)
810-0413
2.16 mm Propane/Butane (G30, G31) (5000-6999 Ft, 1525-2133 M)
812-1028
2.20 mm Propane/Butane (G30, G31) (7000-10,999 Ft, 2134-3352 M)
812-1134
3.10 mm Natural Gas (G20, G25) (0-4999 Ft, 0-1524 M) (Japan only)
810-0403
3.40 mm Natural Gas (G20, G25) (0-4999 Ft, 0-1524 M)
810-0437
3.60 mm Natural Gas (G20, G25) (5000-6999 Ft, 1525-2133 M)
812-1144
3.65 mm Natural Gas (G20, G25) (7000-8999 Ft, 2134-2743 M)
812-1145
3.70 mm Natural Gas (G20, G25) (9000-10,999 Ft, 2744-3352 M)
810-0642
5.95 mm Manufactured Gas (0-4999 Ft, 0-1524 M)
*
826-1196
Conversion Kit, Natural Gas (G20, G25) to Propane/Butane (G30, G31) CE
only
*
826-1197
Conversion Kit, Propane/Butane (G30, G31) to Natural Gas (G20, G25) CE
only
* 807-2263
Switch, Air Pressure (use 807-2262 in units with 100VAC power supply)
* Not illustrated.