Yosemite wood stove, Clearances to combustibles (ul and ulc) – Hearth and Home Technologies Yosemite PMH User Manual
Page 6
R
Page 6
7004-187F September 1, 2008
Yosemite Wood Stove
B
A
C1
Non-fuel
door side
D2
Fuel Door
side
C2
D1
CLEARANCES TO COMBUSTIBLES (UL and ULC)
G
H
E1
E2
F1
F2
Fuel door
side
Non-fuel
door side
G
G*
Max Mantel Depth
10" (254mm)
IF SIDE FUEL LOADING DOOR IS NOT USED:
• It must remain in the locked position at all times
• Use clearances for non-fuel door side for both sides
TOP VENT VERTICAL
A B
C1 C2
D1 D2
E1
E2 F1 F2 G
H
Single Wall-USA
12.5(316) 9(229) 19.5(495) 25.5(648) 10(254) 16 (406) 14(356) 16(406) 18.5(470) 20.5(521) 59(1499) N/A
Single Wall-Canada
12.5(316) 9(229) 19.5(495) 27.5(699) 10(254) 18 (457) 14(356) 18(457) 18.5(470) 22.5(572) 59(1499) N/A
Double Wall-USA
10.5(267) 7(178) 19.5(495) 25.5(648) 10(254) 16(406) 7 (178) 16(406) 11.5(292) 20.5(521) 59(1499) N/A
Double Wall-Canada 10.5(267) 7(178) 19.5(495) 27.5(699) 10(254) 18(457) 7 (178) 18(457) 11.5(292) 22.5(572) 59(1499) N/A
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP
Single Wall-USA
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406) N/A
N/A
N/A
N/A
59(1499) 18*
Single Wall-Canada
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A
N/A
N/A
N/A
59(1499) 18*
Double Wall-USA 11.5(330)
8(203)
19.5(495)
25.5(648)
10(254)
16(406)
N/A
N/A N/A N/A 59(1499)
18*
Double Wall-Canada 11.5(330) 8(203) 19.5(495) 27.5(699) 10(254) 18(457) N/A
N/A
N/A
N/A
59(1499) 18*
90
O
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
Single Wall-USA
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406) N/A
N/A
N/A
N/A
59(1499) N/A
Single Wall-Canada
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A
N/A
N/A
N/A
59(1499) N/A
Double Wall-USA 11(279)
7.5(191)
19.5(495)
25.5(648)
10(254)
16(406)
N/A
N/A N/A N/A
59(1499)
N/A
Double Wall-Canada 11(279)
7.5(191)
19.5(495) 27.5(699)
10(254) 18(457)
N/A N/A
N/A
N/A 59(1499)
N/A
ALCOVE -
Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT listed factory-built Class "A"
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.)
Double Wall-USA 11.5(292)
8(203)
19.5(495)
25.5(648)
10(254)
16(406)
N/A
N/A N/A N/A 42(1067)
N/A
Double Wall-Canada 11.5(292) 8(203) 19.5(495) 27.5(699) 10(254) 18(457) N/A N/A
N/A
N/A 42(1067) N/A
REAR VENT INSTALLATIONS IN A MASONRY FIREPLACE OR THROUGH THE WALL:
Six inch (6") (152mm) diameter
listed double wall air insulated connector pipe with UL103 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home
must be equipped with a spark arrestor). Additional specifications include a MAXIMUM 10" (254mm) MANTEL WIDTH and the following
clearances. Accessory Horizontal Heat Shield, Part HTSHLD-7006, is required for rear vent installations.
Double Wall-USA
N/A 4(102)
19.5(495)
25.5(658)
10(254)
16(406)
N/A
N/A N/A N/A
30(762)
ceiling N/A
Double Wall-Canada
N/A 4(102)
19.5(495)
27.5(699)
10(254)
18(457)
N/A
N/A N/A N/A
30(762)
ceiling N/A
USA or Canada - Single or Double Wall Pipe: 21(533) mantel
*NFPA MINIMUM CLEARANCE - NOT TESTED
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
Max Depth
Min Width
Min Height
Front Door
48(1219)
44(1118)
54(1372)
Side Door-USA
48(1219)
56(1422)
54(1372)
Side Door-Canada
48(1219)
60(1524)
54(1372)
OMNI-Test Laboratories, Inc Safety Report Test Number: 061-S-54-2
Alcove
Vertical
Horizontal
Horizontal, then Vertical