CLEARANCES TO COMBUSTIBLES (UL and ULC)

G

H

E1

E2

F1

F2

Fuel door

side

Non-fuel

door side

G

G*

Max Mantel Depth
10" (254mm)

IF SIDE FUEL LOADING DOOR IS NOT USED:
• It must remain in the locked position at all times
• Use clearances for non-fuel door side for both sides

TOP VENT VERTICAL

A B

C1 C2

D1 D2

E1

E2 F1 F2 G

H

Single Wall-USA

12.5(316) 9(229) 19.5(495) 25.5(648) 10(254) 16 (406) 14(356) 16(406) 18.5(470) 20.5(521) 59(1499) N/A

Single Wall-Canada

12.5(316) 9(229) 19.5(495) 27.5(699) 10(254) 18 (457) 14(356) 18(457) 18.5(470) 22.5(572) 59(1499) N/A

Double Wall-USA

10.5(267) 7(178) 19.5(495) 25.5(648) 10(254) 16(406) 7 (178) 16(406) 11.5(292) 20.5(521) 59(1499) N/A

Double Wall-Canada 10.5(267) 7(178) 19.5(495) 27.5(699) 10(254) 18(457) 7 (178) 18(457) 11.5(292) 22.5(572) 59(1499) N/A

HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP

Single Wall-USA

13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406) N/A

N/A

N/A

N/A

59(1499) 18*

Single Wall-Canada

13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A

N/A

N/A

N/A

59(1499) 18*

Double Wall-USA 11.5(330)

8(203)

19.5(495)

25.5(648)

10(254)

16(406)

N/A

N/A N/A N/A 59(1499)

18*

Double Wall-Canada 11.5(330) 8(203) 19.5(495) 27.5(699) 10(254) 18(457) N/A

N/A

N/A

N/A

59(1499) 18*

90

O

ELBOW OFF TOP OF STOVE THROUGH BACKWALL

Single Wall-USA

13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406) N/A

N/A

N/A

N/A

59(1499) N/A

Single Wall-Canada

13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A

N/A

N/A

N/A

59(1499) N/A

Double Wall-USA 11(279)

7.5(191)

19.5(495)

25.5(648)

10(254)

16(406)

N/A

N/A N/A N/A

59(1499)

N/A

Double Wall-Canada 11(279)

7.5(191)

19.5(495) 27.5(699)

10(254) 18(457)

N/A N/A

N/A

N/A 59(1499)

N/A

ALCOVE -

Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT listed factory-built Class "A"

chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.)

Double Wall-USA 11.5(292)

8(203)

19.5(495)

25.5(648)

10(254)

16(406)

N/A

N/A N/A N/A 42(1067)

N/A

Double Wall-Canada 11.5(292) 8(203) 19.5(495) 27.5(699) 10(254) 18(457) N/A N/A

N/A

N/A 42(1067) N/A

REAR VENT INSTALLATIONS IN A MASONRY FIREPLACE OR THROUGH THE WALL:

Six inch (6") (152mm) diameter

listed double wall air insulated connector pipe with UL103 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home
must be equipped with a spark arrestor). Additional specifications include a MAXIMUM 10" (254mm) MANTEL WIDTH and the following
clearances. Accessory Horizontal Heat Shield, Part HTSHLD-7006, is required for rear vent installations.

Double Wall-USA

N/A 4(102)

19.5(495)

25.5(658)

10(254)

16(406)

N/A

N/A N/A N/A

30(762)

ceiling N/A

Double Wall-Canada

N/A 4(102)

19.5(495)

27.5(699)

10(254)

18(457)

N/A

N/A N/A N/A

30(762)

ceiling N/A

USA or Canada - Single or Double Wall Pipe: 21(533) mantel

*NFPA MINIMUM CLEARANCE - NOT TESTED

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)

NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.

Max Depth

Min Width

Min Height

Front Door

48(1219)

44(1118)

54(1372)

Side Door-USA

48(1219)

56(1422)

54(1372)

Side Door-Canada

48(1219)

60(1524)

54(1372)

OMNI-Test Laboratories, Inc Safety Report Test Number: 061-S-54-2