CONVERTING COLLAR FOR REAR VENT INSTALLATION

1. Lift off cast top. Remove 4 Phillips head screws from the

heat shield. Discard heat shield and save the screws.
Figure 10A

2. Remove 4 Phillips head screws from the rear shield, 2 on

each side, lift shield off and set aside. Figure 10D

3. Remove 1 bolt from each side of the flue transition.

and retrieve nuts attached to bolts. Use 3/8" and 7/16"
wrenches. Figure 10B

4. Turn vent to horizontal position. Inspect sealant to ensure

a leak free application. Figure 10C

5

Manually snap off the knock-out section and discard. See
white outline in Figure 10A.

6. Reattach the rear shield on both sides.
7. Position the bracket (found in the component pack inside

the firebox) over the opening on the rear shield. Use
2 screws removed in Step #1 to secure the bracket.
Figure 10D

8. Place cast top on the unit.

Discard Heat Shield

Knock Out

Section

Figure 10D

Figure 10C

Figure 10B

Attach
bracket
to rear
shield

Bracket

2 screws on

each side

Figure 10E

Figure 10A

HORIZONTAL FLUE HEAT SHIELD

REQUIRED ACCESSORY PART: HTSHLD-7006

Place Horizontal Flue Heat Shield over rear shield as shown
in Figure 10E. Secure with the remaining 2 screws removed
in Step #1 under Reversing Flue Collar.

Secure

Horizontal Flue Heat

Shield

The flue collar is reversible for either a top or rear venting
installation. Accessory Horizontal Flue Heat Shield, Part
HTSHLD-7006, is required in rear vent installations. The
stove is shipped with the flue collar in the top vent position.

REVERSIBLE FLUE COLLAR