beautypg.com

Harman Stove Company Harman Stove The Harman Magnum Stoker User Manual

Page 18

background image

18

DO NOT BURN WET COAL

The installation should be performed by your dealer who is factory

trained to correct any problem on initial start-up. After proper installation,
many years of trouble-free operation can be expected.

Stoker Control Trouble-Shooting

This trouble-shooting guide is designed to help the customer find basic

problems external to the stoker timer. If a problem cannot be located by
using this guide, servicing of the stoker control or replacement may be
required. This should be done by qualified personnel.

PROBLEM: No motors or lights will turn on.

Check the AC power cord to the stoker control.

Check the 3 amp fuse on the side panel of the stoker timer. (Replace

only with a 3 amp slow blow fuse.)

PROBLEM: Lights on the stoker control are on, but motors will not

operate.

Check the AC power plugs from the motors (are they securely

plugged into the correct outlet.)

PROBLEM: One of the motors will not operate.

Check if the light above the receptacle is lit. Check the AC power

plug from the motor (is it securely plugged into the correct outlet.)

PROBLEM: The motors are cycling on and off, but not in the correct

order.

Check the AC power plugs from the motors (are they securely

plugged into the correct outlet.)

PROBLEM: Coal feeder motor will not turn on.

Check if the red light is lit, if not, check if the feed motor switch is

turned on.

PROBLEM: The motors turn on and off as programmed, but the

room temperature is below the thermostat setting.