Henny Penny BFR/BCR-350 User Manual
Page 9

Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350
503
2-3
2-3. ELECTRICAL
Refer to the table below for electrical ratings for both models.
(Continued)
Model No.
Volts
Watts
Amps
Freq.
Phase
BCC-140
200
4700
18
50/60
3
208-240
4700
18
60
3
230
4700
20
50
1
BCC-175
200
5800
20
50/60
3
208-240
5800
20
60
3
400
5800
9
50
3N
BCR-140
200
2400
12
50/60
1
208-240
2400
12
60
1
230
2400
10
50
1
BCR-175
200
2400
12
50/60
1
208-240
2400
12
60
1
230
2400
12
50
1
BFR &
200
4100
15
50/60
3
BCR-350
208-240
4100
15
60
3
400
4100
10
50
3N
2-4. LOCATION
The blast chillers should be placed in an area where the doors can
be opened, for loading and unloading, without interruption. For
proper operation and door closure, the cabinet must be level.
When placing models BFR/BCR-350 in a location, take into
account the effect the cooling temperatures will have on the floor
surface (ex: temperature rentention, condensatin under the flooring,
frost, etc.). Damage to the floor could result.
For maximum efficiency, if the air temperature of the premises
is more than 100° F (38° C), the room should have adequate
ventilation, taking into account for the heat emitted by the unit.