Henny Penny BFR/BCR-350 User Manual
Page 12

Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350
2-5. REFRIGERANT
INFORMATION
Design Pressure
Refrigerant Type Amount of Refrig. High Low
BCC-140
R404A
6 lbs. (2.7 kg)
406 psig
102psig
(28 bar)
(7 bar)
BCC-175
R404A
5.5 lbs. (2.4 kg)
406 psig
102 psig
(28 bar)
(7 bar)
2-6. REFRIGERATION
BCC/BCR-140
CAPACITIES
-4
o
F (-20
o
C) at 6,800 BTU/hr (2.0 kw)
32
o
F (0
o
C) at 16,000 BTU/hr (4.7 kw)
BCC/BCR-175
-4
o
F (-20
o
C) at 11,300 BTU/hr (3.3 kw)
32
o
F (0
o
C) at 30,800 BTU/hr (9.0 kw)
BCR-350
-4
o
F (-20
o
C) at 25,000 BTU/hr (7.3 kw)
32
o
F (0
o
C) at 58,000 BTU/hr (17.0 kw)
BFR-350
-4
o
F (-20
o
C) at 81,900 BTU/hr (24.0 kw)
-40
o
F (-40
o
C) at 35,500 BTU/hr (10.4 kw)
2-6
1105
2-7. BCC-175 WATER SUPPLY
AND DRAIN
Water Supply
• Water temperature should be at 50
o
F (10
o
C) + 5
o
)
• 1/2”-14 (15mm/21) diameter water supply
• 29 psi (2 bar) minimum pressure; 73 maxmum (5 bar)
• Supply inlet connector 3/8”-18 (12mm/17)
• 24.7 foot3/hour (0,7 m3/hour) minimum flow rate
Check the operation of the pressure valve. Water should not flow
after the compressor stops. Adjust the valve where necessary,
checking the condensation pressure.
Do not change any supply fittings or lines installed by the manu-
facture, or damage to the unit could result.
Do not use a flexible connection to make a drain trap, or water
overflowing the drain could result.