beautypg.com

Henny Penny BFR/BCR-350 User Manual

Page 15

background image

Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

2-9. REMOTE CONDENSING
UNITS INFORMATION
(Continued)

Refrigeration Capacities
We provide refrigeration capacity at two evaporation temperatures.
• Blast Chiller : 0°C (32°F) and –20°C (-4°F).
• Blast Freezer –20°C (-4°F) and –40°C (-40°F). Combined

units (Chiller/Freezer) are basically Blast Freezers.

The remote condensing units have to be selected in accordance with
these two data points. Refrigeration capacity of remote condensing
units have to be equal or higher than the requirement.

Example for a Blast Chiller:
Evaporation temperatures

0°C (32°F)

-20°C (-4°F)

Refrigeration capacity needed

17000 W

7300 W

Remote condensing unit A

16900 W

7500 W

No Good

Remote condensing unit B

17100 W

7280 W
No Good

Remote condensing unit C

17010 W

7310 W

Both Work

Blast Chiller/Freezers start-up at high internal air temperature,
because of the hot food. The condensing unit runs at a high evapo-
ration temperature at beginning of the cycle and a low evaporation
temperature at the end of the cycle, when the food is cooled down.

Usually a single evaporation temperature is used when
specifying a condensing unit, because cold cabinets and
cold rooms run at a single temperature. But, blast chiller/
freezers require both data points, or the blast chiller/
freezer may not hold product at safe temperatures.

605

2-9

This manual is related to the following products: