3-7. PROGRAMMING

Information about the operation settings can be accessed by
pressing . These settings can also be changed while in the

different steps. The following information can be accessed:

After pressing , a delay occurs before the desired
number appears in the display, and the number in the left
column shows for 2 seconds. You then only have 12 seconds
to change the setting.

Not Available at this time.

Not Available at this time.

Internal air temperature. Press three times and the
digital display shows the air temperature during a Probe Cycle.

Evaporator temperature. Press 4 times and the digital
display shows the evaporator temperature during the De-icing
Cycle.

Type of program setting indicated by the jumper
link located on the control board.
Press

5 times and

the digital display shows a number between 5 and 9, which
indicates the position of the jumper on the control board. The
control panel area does not have to be accessed to obtain the
information. (See chart at left.) Henny Penny controls should
show the number 6 in the display.

Temperature of the Holding Cycle, after the Chilling or
Freezing Cycle.
Press 6 times and the digital display
shows the air temperature. This is the temperature at which the
unit stays during the Hold Cycle.

3-10