Planar Systems UltraRes P Series 49" UHD 4K Commercial Monitor User Manual
Page 53

53
Planar UltraRes P Series User Manual
020-1407-02A
Page | 53
Power Saving Delay
• Sets the amount of time before initiating the standby state specified in
Power Saving
Mode
when no signal is present
•
Options:
1 Minute, 5 Minutes, 15 Minutes, 30 Minutes, 60 Minutes;
Default:
5 Minutes
Power On Delay (URP75 / URP85 / URP98 only)
• Sets the amount of time to delay between an ON command being received and the display
leaving standby. This can be useful when multiple displays are on the same electrical
circuit, and it is beneficial to avoid all displays leaving standby simultaneously, causing a
large inrush of current.
•
Options:
0-10 seconds, in 0.1 second increments;
Default:
0 seconds
Power Down Mode
• Set the action to take when the display enters standby
•
Options:
Standby Mode, Networked Standby Mode, Fast Startup;
Default:
Standby Mode
•
Standby Mode:
The lowest power standby setting. CEC, LAN, DB9 RS232, and USB
communication are disabled. IR, Keypad connector will remain active.
•
Note:
To remove display from standby with the IR remote or keypad, IR Remote Lock
or Keypad Lock must be disabled.
•
Note (URP75 / UPR85):
The Turn On action in the Schedule feature will not work if the
Power Down Mode
setting is set to
Standby Mode
. To allow the Turn On action to
occur, set
Power Down Mode
to
Networked Standby Mode
or
Fast Startup
.
•
Networked Standby Mode:
The display will enter a low power standby state with LAN,
DB9 RS232, USB and IR communications active.
•
Fast Startup:
The display will enter a standby state with partially reduced power, allowing
for 3-5 second wait between an ON command being sent, and image being displayed. IR,
Keypad, CEC, LAN, DB9 RS232, and USB communication will remain active.