Planar Systems UltraRes P Series 49" UHD 4K Commercial Monitor User Manual
Page 52

52
Planar UltraRes P Series User Manual
020-1407-02A
Page | 52
Power Submenu
Auto Power On
• If set to On, the display will automatically leave standby after AC power is applied
•
Options:
On, Off;
Default:
Off
•
Note:
URP49 / URP55 / URP65 also includes Previous State. If selected, when the
display is on and loses power, it will go to the last operational state when power is
restored.
Power Saving Mode
• Set the action to take if there is no signal detected after the period of time specified by the
Power Saving Delay
setting
•
Options:
Disabled, Power Down, Wake on Signal;
Default:
Disabled
•
Disabled:
Once powered on, the display will remain on even if no signal is present.
•
Power Down:
The display will enter a standby state specified by the
Power Down
Mode
setting.
•
Wake On Signal:
The display will enter a standby sleep mode if no signal is detected.
The display will wake when signal is restored.
•
Note:
When signal is restored, a 10-15 second wait is typical to have an image
displayed.
•
Note:
The display must be allowed to enter sleep mode due to lack of signal for
Wake On Signal
to take effect. Sending an OFF command via Keypad, IR, CEC,
RS232 or LAN will bypass
Wake On Signal
detection, and the display will enter the
power state specified in the
Power Down Mode
setting.
•
Note:
If
Auto Scan Sources
is enabled in the
Inputs and Views
menu, the
display will sequentially scan all inputs before entering sleep mode. The display will
leave sleep mode when a signal is detected on any input.
•
Note:
If
Auto Scan Sources
is disabled in the
Inputs and Views
menu, the
display leave sleep mode only when a signal is detected on the last selected input.
•
Note:
When
Wake On Signal
is selected, the LAN port and
Remote Monitoring
web interface will remain accessible after the display enters sleep mode.