beautypg.com

Protection function, Over-temperature protection – Godox TT600 Thinklite Flash User Manual

Page 17

background image

- 34 -

1. Over-Temperature Protection

● To avoid overheating and deteriorating the flash head, do not fire
more than 30 continuous flashes in fast succession at 1/1 full

power. After 30 continuous flashes, allow a rest time of at least 10

minutes.
● If you fire more than 30 continuous flashes and then fire more

flashes in short intervals, the inner over-temperature protection

function may be activated and make the recycling time about 10

to 15 seconds. If this occurs, allow a rest time of about 10

minutes, and the flash unit will then return to normal.
● When the over-temperature protection is started,

is shown on

the LCD display.

Number of flashes that will activate over-temperature
protection:

Power Output Level

Number of Flashes

1/1

30

1/2 +0.7

40

1/2 +0.3

50

1/2

60

1/4

+0.3,+0.7

100

1/8

+0.3,+0.7

200

1/16

+0.3,+0.7

300

1/32

+0.3,+0.7

500

1/64

+0.3,+0.7

1000

1/128

+0.3,+0.7

Number of flashes that will activate over-temperature protection
in high-speed sync mode:

Power Output Level

Number of Flashes

1/1

15

1/2

+0.3,+0.7

20

1/4

+0.3,+0.7

30

1/8

+0.3,+0.7

1/16

+0.3,+0.7

40

1/32

+0.3,+0.7

1/64

+0.3,+0.7

50

1/128

+0.3,+0.7

Protection Function