Set flow sensor model, Set flow unit, Read/learn station flow value – Irritrol MC-E User Manual
Page 38
Set Flow Sensor Model
Flow Sensor Data Table
Step 1 – Place the Function dial to the FLOW
SENSING
position. Enable
flow sensing if its disabled.
Step 2 – While in the K Value/Sensor Size
screen, select the flow sensor size
code by pressing the
button.
Use the Flow Sensor table below to
find your specific size code.
Example: If using Sensor Model
TFS-075, press the
button until
the S value in the display equals 75
(S=75).
Set Flow Unit
Step 1 – Place the Function dial to the FLOW SENSING
position. Enable flow sensing if its disabled.
Step 2 – Press the
button to change the flow unit. Press the
button repeatedly until the desired flow unit is
displayed (GPM = Gallons per Minute, CFM = Cubic Feet per Minute, CMH = Cubic Meter per Hour,
LPM = Liter per Minute or PPS = Pulses per Second).
If the sensor you choose is not represented on the chart, use “Unknown Flow Sensor” size code “00”. The flow
unit for “Unknown Flow Sensor” can only be set to PPS.
Read/Learn Station Flow Value
Step 1 – Place the Function dial to the FLOW SENSING
position. Enable flow sensing if its disabled.
Step 2 – Verify that all flow parameters are set, then press the
button to read/learn each of the station’s actual
flow. It will read/learn the station’s flow value until the flow delay time expires. The default flow delay is one
minute. During “Learn Flow” each station will be displayed with the flow that the sensor is measuring.
To learn the flow value of a specific station, enter the two digit station number and press the
button.
To learn the flow value of a group of stations, enter the two digit station number of the 1st station, the two digit
station number of the last station and press the
button. The MC-E will sequentially read the flow value for
each station in the group.
Step 6 – To review each station flow parameters, press the
button. MC-E will sequentially display each of the
station’s flow parameters.
Flow Sensor Model
K Value
Offset
GPM
L/Sec
Size
Code
Pipe
Size
Unkown Flow Sensor
00
Unkown
1
0
PPS
PPS
TFS-050
50
1/2’’
0.07800
0.9
1.2 – 12
0.1 – 0.8
TFS-075
75
3/4’’
0.15630
0.9
2.7 – 28
0.2 – 1.8
TFS-100
100
1’’
0.26112
1.2
5.0 – 50
0.3 – 3.2
TFS-150 or 228PV15xx-xxxx
150
1.5’
1.69900
-0.3160
5 – 100
0.3 – 6.3
TFS-200 or 228PV20xx-xxxx
200
2.0’’
2.84290
0.14350
10 – 200
0.6 – 12.6
TFS-300 or 228PV30xx-xxxx
300
3.0’’
8.30900
0.22700
20 – 300
1.3 – 18.9
TFS-400 or 228PV40xx-xxxx
400
4.0’’
13.74283
0.23707
40 – 500
2.5 – 31.5
250BR0700x-xxxx
7
3/4’’
0.43680
0.56800
250BR1000x-xxxx
10
1’’
0.39740
0.26180
0.25 Liters Per Pulse
11
0.25 L/P
1
0
0.50 Liters Per Pulse
12
0.50 L/P
1
0
1 Liter Per Pulse
13
1 L/P
1
0
2.5 Liters Per Pulse
14
2.5 L/P
1
0
5 Liters Per Pulse
15
5 L/P
1
0
10 Liters Per Pulse
16
10 L/P
1
0
25 Liters Per Pulse
17
25 L/P
1
0
50 Liters Per Pulse
18
50 L/P
1
0
100 Liters Per Pulse
19
100 L/P
1
0
250 Liters Per Pulse
20
250 L/P
1
0
500 Liters Per Pulse
21
500 L/P
1
0
1000 Liters Per Pulse
22
1000 L/P
1
0