8. SERVICE AND OPERATION DISTURBANCES
The amount of use and working environment should be taken into consideration when planning
the frequency of maintenance of PROMIG. Careful use and preventive maintenance will help to
ensure trouble-free operation.
Following maintenance operations should be carried out at least every six months:
Check:
– Feed roll grooves. Excessive wear of grooves causes wire feed
problems.
– Wire guide tubes. Badly worn feed rolls and wire guide tubes
should be discarded.
– Wire guide tube in the gun should be set as near the feed rolls
as possible and the wire must follow a straight line from the end
of the tube to the groove of the feed roll.
– Reel brake adjustment.
– Electrical connections:
* Oxidized couplings must be cleaned
* Loose couplings must be tightened
Clean dust and dirt from the equipment.
twice a year
When using compressed air, always protect your eyes with proper eye
protection.
In case of problems contact your KEMPPI dealer.
7. ERROR CODES OF PANELS
Error codes inform the user about welding system malfunctions. They are displayed on MC/ML
panels.
Err 1 Robot identification failed. Robot identification is done using XW114 on A003 X8.
Err 2 Power source has been started for MMA or TIG mode.
Err 3 Same as Err 2 but up (+) / down (–) buttons are active on PX panel (optional).
Err 4 Cooling unit (Procool 10 / 30) is not starting (check gas/water switch).
Err 5 Cooling unit (Procool 10 / 30) has a cooling failure (overheating sensor or pressure
switch has reacted or unit is missing supply voltage).
Err 6 Water unit (Procool 10 / 30) has been started normally, but wire feed unit
(Promig 540R) has lost serial communication link to cooling unit (check interconns).
Err 7 Emergency stop is active. Input relay K2 must be active on A003 to cancel emergency
stop (only Promig 540R - KU).
Err 9 Overload of wire feed motor which may be caused by blocked wire guide of gun or by
gun cable which is too curved.
Err 10 PRO power supply reports error when start message from Promig 540R is sent.
Operation of thermal protection of PRO power source has stopped welding.
Err 14 Supply overvoltage in Promig 540R.
Error code display is cleared by next start if the cause of error code has been eliminated.