5. OTHER USER FUNCTIONS
Selection between gas-cooled and water-cooled gun is made using the switch inside the control
unit.
Wire inch switch function is in the front of control unit and feeder unit.
– displays main motor current on welding current window and gun motor current on voltage
display window
– inch speed is set by local control setting (panel)
Gas purge switch is in the front of control unit and feeder unit.
– gas purge when pressed
Gas valve is mounted inside the feeder unit but it can also be moved into the control unit where
there is a place for it.
A gas pressure switch can be mounted inside the control unit.
Inside the control unit there is a 20 kg MIG wire spool system.
6. JUMPERS
1. Selection of wire feeder address
102, set 1
105, set 2
2. Robot control input voltage range for analog channels:
0-10 V
0-5 V
3. Selection of max. wire feed speed for feed unit 1
0-18 m, delivery setting
0-25 m
4. Selection of max. wire feed speed for feed unit 2
0-18 m / min
0-25 m / min