beautypg.com

Dataprobe T-APS Rack User Manual

Page 15

background image

Set Buildout (Network)

T1 Setting Selection

(A) DSX1-1:

0 to 133 feet

(B) DSX1-2:

133 to 266 feet

(C) DSX1-3:

266 to 399 feet

(D) DSX1-4:

399 to 533 feet

(E) DSX1-5:

533 to 655 feet

(F) -7.5dB CSU

(G) -15dB CSU

(H) -22dB CSU

E1 Setting Selection

(A)120 Nor:120 ohm Normal Return Loss.

Recommended setting for (1) stable T1/E1 circuits or (2) short distance between
T-APS-R and the connected next equipment. For example, T-APS-R to HDSL.
(In general, set 120Nor)

(B)120 Hi:120 ohm High Return Loss.

Recommended setting for (1) unstable T1/E1 circuits or (2) long distance

between T-APS-R and the next connected equipment. (200 meters or more)

Set Receive Sensitivity (User)

LONG: T1 Setting Sensitivity is –36 dB

E1 Setting Sensitivity is –43 dB

SHORT: T1 Setting Sensitivity is –15 dB

E1 Setting Sensitivity is –12 dB

Set Buildout (User)

T1Setting

(A) DSX1-1: 0 to 133 feet

(B) DSX1-2: 133 to 266 feet

(C) DSX1-3: 266 to 399 feet

(D) DSX1-4: 399 to 533 feet

(E) DSX1-5: 533 to 655 feet

(F) -7.5dB CSU

(G) -15dB CSU

(H) -22dB CSU

E1 Setting

(A) 120 Nor:120 ohm Normal Return Loss

(B) 120 Hi¡G120 ohm High Return Loss