beautypg.com

Set line configuration – Dataprobe T-APS Rack User Manual

Page 14

background image

Enable Look-In Mode

T-APS-R units will do a checking function to the CPE signal before switching from active path to
the protection path.

Enable: T-APS-R will be enabled to check CPE signals. In the event of excessive bit

errors from the CPE side to T-APS-R, T-APS-R will not perform switching. Enable
Look-In may increase a few mili-second to the switching time.

Disable: T-APS-R will be disabled to check CPE signals. In the event of excessive bit

errors from the CPE to T-APS-R, T-APS-R will perform switching in all events
including excessive bit errors from CPE side

Set Line Configuration

Set Line Format

T1 Setting Selections

UNFRAMD: Unframe

SF: SuperFrame

ESF: Extended SuperFrame

E1 Setting Selections

CAS: Channel Associated Signaling (for voice)

CCS: Common Channel Signaling (for data)

CAS&C: Channel Associated Signaling & CRC-4 (Cyclic Redundancy Check 4)

CCS&C: Common Channel Signaling & CRC-4

Set Line Code

T1 Setting Selections

B8ZS: Bipolar 8-zero substitution or Binary 8-zero substitution.
AMI: Alternate Mark Inversion

E1 Setting Selections

HDB3: High-Density Bipolar order 3 encoding.

AMI: Alternate Mark Inversion

Set Receive Sensitivity (Network)

LONG : T1 Setting Sensitivity is –36 dB

E1 Setting Sensitivity is –43 dB

SHORT: T1 Setting Sensitivity is –15 dB

E1 Setting Sensitivity is –10 dB