Setting the EMG

Aux Mute on the Innovator

(1) Auxiliary Inputs

(4) EMG Input

1

4

4

To activate the mute function,

use a terminal jumper to connect

the +24 V BIAS terminal (4) and

the EMG CNT terminal . With the

jumper in place, the auxiliary

inputs will be muted when a

page is received . To deactivate

the muting function, connect

the EMG terminal to the EMG

GND terminal as shown in the

diagram at right .

Notes:

The AUX mute for the PA input terminal operates independently from the teacher

voice mute settings .

Setting the Emergency Mute Function

The Emergency Mute Function (EMG) (4) allows the user to select whether auxiliary input

devices are muted during PA system announcements .