A power switch (#1) is located on the left side of the SiteSync IQ Wireless Controller. When power is connected and the power

switch is in the on position the power LED (#2) located in the top right corner of the front panel will light red.

WARNING

The power switch only removes power to the internal circuitry of the SiteSync IQ Wireless Controller. If performing

maintenance within the wiring panel located at the bottom of the SiteSync IQ Wireless Controller, power should be

removed prior to service.

Bell Relays

The SiteSync IQ Wireless Controller can be thought of as an extension to the SiteSync IQ System Controller wired relays. When

the SiteSync IQ System Controller activates its on-board wired relays, it also sends out a message to activate the SiteSync

IQ Wireless Controller relays. Each wired relay on the System Controller corresponds to the same wired relay on the Wireless

Controller: i.e. Bell one on the system controller corresponds to bell one on the wireless controller; Bell two corresponds to bell

two, and so on.

Each Wireless Controller bell relay comes equipped with a three position switch (#3). These switches allow the user to manually

operate each circuit, turn them off or allow automatic control from the SiteSync IQ System Controller via wireless signals.

The bell relays on the SiteSync IQ Wireless Controller can be manually activated by moving the corresponding switch to the top

(On or Test) position. A red LED will light indicating that the relay is currently active.

To disable a relay simply place the corresponding switch in the center position. The LEDs above and below the relay switch will

turn off when the corresponding switch is in the OFF position.

Automatic bell relay operation is achieved by placing the corresponding switch in the down (Auto) position. In this position the

SiteSync IQ System Controller has complete control of the bell relay. A yellow LED will light indicating the relay is ready for a

message from the System Controller. A red LED will light indicating the relay is active.

Front View - Open

Side & Front View

1

2

3

4

5

8

7

6

9

10

11

12

13

14

15

16

17

18

19

1. Power Switch

2. Power LED

3. 3 Position Relay Switches

4. RCA Jack

5. Tone Card

6. Bell Relay 1 Surge Switch

7. Bell Relay 2 Surge Switch

8. Bell Relay 3 Surge Switch

9. Bell Relay 4 Surge Switch

10. Power Input Fuse

11. Hot

12. Neutral

13. Ground

14. Relay Connections

15. Relay Output Fuses

16. NC Surge Switch

Clock B

17. NO Surge Switch

Clock B

18. NC Surge Switch

Clock A

19. NO Surge Switch

Clock A