beautypg.com

Appendix c: clock relay wiring diagram, Wired clock circuit installation – American Time Wireless Controller User Manual

Page 12

background image

© American Time

12

SiteSync IQ Wireless Controller

Installation Manual

Appendix C: Clock Relay
Wiring Diagram

Appendix

Tr

oubleshooting

Operation

Contr

oller

Installation

Intr

oduction

Clock Code 01 - 3 wire Synchronous

NO

C

NC

C

NO

NC

BELL 5/CLK A

BELL 6/CLK B

CORRECTION

RETURN

RUN MOTOR

AC RTN

120/24 VAC

To install wired clock circuits:
1. Disconnect and lock out power to the SiteSync IQ Wireless Controller and any circuit wiring.
2. Remove the cover from the Wireless Controller.
a. Remove 2 screws from each side of the wire compartment cover.
b. Remove the wire compartment cover.
3. Route clock circuit wires into the wiring compartment of the Wireless Controller.
a. Remove knockout(s) below wire compartment.
b. Use copper conductors only.
c. Use strain relief connector fittings in the knockout holes to secure the wires.
d. Route the wires into the wiring compartment, leaving enough slack to make all connections to the relay terminals.
4. Connect clock wires to the circuit relay terminals.
5. Replace the wire compartment cover.
6. Apply power to the wireless controller and clock circuit(s).
7. Test the clock circuit. Clock relay B should activate at HH:57:54 for 8 seconds and at 05:57:54 for 14 seconds.