beautypg.com

Wiring configurations, Wiring configuration 1, Example 1-1 – American Time Wired Audio Generator User Manual

Page 9

background image

9

© American Time

Wired Audio Generator

Installation Manual

W

iring

Configurations

Operation

Inputs/Outputs

Intr
oduction

Wiring Configurations

Wiring Configuration 1

One of the most common applications for the Audio Generator is to wire it directly to the bell circuits of the SiteSync IQ system

controller. Here, background music (BGM) from another source can also be played through the Audio Generator to a PA system

while the MP3 files are not being triggered or played. The following are four examples of this configuration.

Example 1-1

In this example, a SiteSync IQ system controller can trigger the Audio Generator to play 6 specific MP3 files.
Example: A school is playing 3 of 6 different bell tones at specific times during the day.

•At 8:00 a.m. a morning, or start of day, a custom bell/tone is played (1.mp3)

•At 12:00 p.m. a lunch time a custom bell/tone is played (2.mp3)

•At 4:15 p.m. an end of day a custom bell/tone is played (3.mp3)

Example of Schedule for SiteSync IQ system controller:

Audio Generator DIP Switch Settings

Position 5

OFF Standard

Positon 6

OFF Play Once

Event Tab

Circuit Tab

See wiring on page 10