Wiring Configurations

Wiring for Example 1-3

REAR OF SY

STEM C

ONTR

OLLER

COM

NO

NC

NC

COM

NO

NO

COM

NO

COM

COM

NO

NO

COM

NO

COM

NO

COM

CLOCK 1

CLOCK 2

BELL 1

BELL 2

BELL 3

BELL 4

BELL 5

BELL 6

1

2

3

4

5

6

8Ω -

-

+

+

8Ω

600Ω

600Ω

Background
Music Source

Audio
Generator

PA System

Example 1-4

In this example the Audio Generator can be used in conjunction with either another Audio Generator or a standard tone generator

to coordinate a scheduled playing of tones and music with the SiteSync IQ system controller.
Example 1-4A: A school is triggering a tone at the start and end of each class and classical music for the three minutes between

tones using a SiteSync IQ system controller, one Audio Generator and one tone generator

•At 8:57 a.m. Bell Circuit 1 from the system controller will trigger the tone generator to play an end of class tone

•At 8:57 a.m. Bell Circuit 2 will trigger the Audio Generator to play classical music (saved as MP3’s)

•At 9:00 a.m. Bell Circuit 3 will trigger the Audio Generator to STOP playing the music

•At 9:00 a.m. Bell Circuit 1 will trigger the tone generator to play a start of class tone

The announcement in this example could also be triggered to run at a specific time and date. The schedule would be set up in

the SiteSync IQ system controller just as the custom bell/tones were in the previous examples.