Wiring configurations, Example 1-4 – American Time Wired Audio Generator User Manual
Page 13
13
© American Time
Wired Audio Generator
Installation Manual
W
iring
Configurations
Operation
Inputs/Outputs
Intr
oduction
Wiring Configurations
Wiring for Example 1-3
REAR OF SY
STEM C
ONTR
OLLER
COM
NO
NC
NC
COM
NO
NO
COM
NO
COM
COM
NO
NO
COM
NO
COM
NO
COM
CLOCK 1
CLOCK 2
BELL 1
BELL 2
BELL 3
BELL 4
BELL 5
BELL 6
1
2
3
4
5
6
8Ω -
-
+
+
8Ω
600Ω
600Ω
Background
Music Source
Audio
Generator
PA System
Example 1-4
In this example the Audio Generator can be used in conjunction with either another Audio Generator or a standard tone generator
to coordinate a scheduled playing of tones and music with the SiteSync IQ system controller.
Example 1-4A: A school is triggering a tone at the start and end of each class and classical music for the three minutes between
tones using a SiteSync IQ system controller, one Audio Generator and one tone generator
•At 8:57 a.m. Bell Circuit 1 from the system controller will trigger the tone generator to play an end of class tone
•At 8:57 a.m. Bell Circuit 2 will trigger the Audio Generator to play classical music (saved as MP3’s)
•At 9:00 a.m. Bell Circuit 3 will trigger the Audio Generator to STOP playing the music
•At 9:00 a.m. Bell Circuit 1 will trigger the tone generator to play a start of class tone
The announcement in this example could also be triggered to run at a specific time and date. The schedule would be set up in
the SiteSync IQ system controller just as the custom bell/tones were in the previous examples.
Event Tab for 1-4A