Appendix: DEC 3 Installation and Operation
IMPORTANT Tempest enclosures are supplied for either 120VAC 50/60Hz, or 208-240VAC,
50/60Hz operation. Tempest Lighting is not liable for damage or failure to
operate correctly due to connection to an inappropriate electrical supply.
ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A QUALIFIED
ELECTRICIAN, IN COMPLIANCE WITH LOCAL NORMS AND STANDARDS.
Split or Common Supply Wiring
NOTE:
Your enclosure MUST run 24/7, in order to protect equipment from condensation
and temperature extremes.
Tempest Enclosures are supplied wired for common electrical supply for the enclosure
(DEC3) and the projector/light fixture to be enclosed. Customers wishing to provide
independent electrical feeds to the enclosure and the projector/fixture must follow the
instructions below.
Feeder Connections – Common Feed
Feeder Connections, Split Feeds
Note: terminals shown with gray text descriptors are factory wired and should not be changed. Only terminals
shown with descriptors in black/bold font are for installer use.
DEC3 normally ships from the factory with power terminal links inserted for a common electrical
supply to feed the enclosure and the projector/fixture inside it.
If you prefer to feed the enclosure and projector separately, remove the terminal links as indicated
before connecting to mains power. Use a small flat-bladed screwdriver to remove the link, snap off the
unneeded section and replace carefully. When splitting the feeders, we strongly recommend feeding
both supplies from the same phase and at the same supply voltage.
Live: Heater
Live: Fan
Live: Fan
Live: Fan
Live: Projector Feed
Neutral: Projector Feed
Neutral: Heater
Neutral: Fan
Neutral: Fan
Neutral: Power In
Neutral: Fan
No Connection
No Connection
Live: Power In
No Connection
Ground
Ground
Live: Heater
Live: Fan
Live: Fan
Live: Fan
Live: Projector Feed
Neutral: Projector Feed
Neutral: Heater
Neutral: Fan
Neutral: Fan
Neutral: Enclosure Power In
Neutral: Fan
Neutral: Projector Power In
Live: Projector Power In
Live: Enclosure Power In
No Connection
Ground
Ground
REMOVE LINKS