beautypg.com

Spectrum Controls 1769sc-HART Modules User Manual

Page 94

background image

User’s Man

7-28

Section
Module
Comma

Compac

nual 0300217-

n 7.4

Specific

ands

ct IO™ Isolate

03 Rev. A

The HART o
include the H
information.
Since some m
module 40 b

The module
7-8 using a J
the message
and stored in
figure below
Figure 7-9 (

The tables o

7.4.1 Get

The Get HAR
information
Table 7-11.
information
Get HART D
RAM and no


Table 7-9 (G

HART Get D
Get currently
Field
HART Chann
Number

Command Nu

Input Par: M
Input Par: M
Return Par: M
Return Par: M

ed HART Anal

output module

HART pass-thr

. The comman

messages can b

bytes at a time u

specific comm

JSR instruction

to the module

n a temporary a

w.

(Message Flow

n the following

HART Dev

RT Device Info

for the connec

The informati

gathered from

Device Informa

ot directly from

Get HART De

Device Informat

cached Device I

Va

nel 0x

umber

0x

Message Size
Message Body (i.e.

Message Done
Message Response

JSR

log Output Mo

uses module s

rough, HART s

nds are passed t

be as long as 2

using the pagin

mand and accom

n with paramet

. The response

array where it c

w)

g pages show t

vice Informa

ormation comm

cted HART dev

on that is gathe

the auto-acqui

ation command

m the field devi

evice Informat

tion – command

Information for a

alue

x00 – 0x03 (1 by

x03 (1 byte)

Device Specific C

e (i.e. Temp Array

odule

specific comma

suspend and re
to the module u

257 bytes, the d

ng scheme des

mpanying data

ters. When the

e data, if any, i

can be used wi

the format for e

ation

mand is used to

vice. The data

ered by this co
isition process

d pulls the data

ice.

tion Comman

d message pack

a given channel.

yte)

Command)

y)

ands. Module

esume, and get

using the input

data is transpor

cribed in the p

a is passed to th

e routine is exe

is also converte
ithin the ladder

each module sp

o gather the dev

that is retrieve

ommand is sim
s. The key diff

a that has been

nd)

ket structure

.

R

F

specific comm

t HART device

t and output im

rted to and from

previous section

he routine in Fi

ecuted it will se

ed by this rout

r program. See

pecific comma

vice specific

ed can be seen

milar to the

ference is that t

stored in the m

Definition
Module input
channel number
HART comman
The command
number to obtai
HART device
information

Routine

Fig 7.9

mands

e

mage.

m the

n.

igure

end

ine

e

and.

in

the

module

r for

nd

in