Installation – Glow-worm Ultracom2 cxi User Manual

Page 24

background image

0020085231_02 - 05/10 - Glow-worm

- 22 -

11.3 Electrical wiring

Connection of the whole electrical system and any heating

system controls to the electrical supply must be through a

common isolator.

Isolation should preferably be by a double pole switched fused

spur box having a minimum contact separation of 3mm on each

pole. The fused spur box should be readily accessible and

preferably adjacent to the boiler. It should be identified as to its

use.

A fused three pin plug and shuttered socket outlet may be used

instead of a fused spur box provided that it is not used in a

room containing a fixed bath or shower.

24

V

1

Key

1 Power supply cable

• Connect the appliance's power cable to the 230 V single-

phase network + earth.

• Connect the appliance in accordance with the live and

neutral connections.

11.3.1

230V permanent supply

a

All cables connected to the appliance should be

permanently fixed to the wall.

i

This appliance will not operate without a link or

system controls fitted.

24

V

3

4

1

2

Key

1 230V permanent supply

2 Main board terminal block

= Mains earth

N = Mains neutral

L = Mains live

3 fuse

4 Double pole connector

• Connect mains supply as described.

INSTALLATION