Installation, 7 appliance installation, 1 scope of delivery – Glow-worm Ultracom2 cxi User Manual

Page 12: 2 recommendations before installing

background image

0020085231_02 - 05/10 - Glow-worm

- 10 -

7 Appliance installation

7.1

Scope of delivery

The appliance is delivered in a single carton with a document

pack and fittings.

i

The flues package will be ordered according to the

configuration of the installation.

• Please check the contents.

1

4.7

2.1

2

2.2

2.3

2.5

2.6

3

2.4

4

4.1

4.2

4.3

4.4

4.5

4.6

Key

1

boiler

(x1)

2

Accessories bag

(x1)

2.1

Pressure relief valve connecting pipe

(x1)

2.2

Connection bag

(x1)

- Heating return valve

(x1)

- Cold water inlet valve

(x1)

- Heating flow valve

(x1)

- Domestic hot water connection

(x1)

- Gas isolation valve

(x1)

2.3

Hanging bracket

(x1)

2.4

filling loop extensions

(x2)

2.5

Seals bag

(x1)

- flat seal ½"

(x2)

- flat seal ¾"

(x5)

- Flat seal for cold water inlet ¾"

(x4)

2.6

Compression fitting

(x1)

3

Wall template

(x1)

4

Documents bag

(x1)

4.1

Installation and servicing manual

(x1)

4.2

flue book

(x1)

4.3

Instructions for use

(x1)

4.4

Extended guarantee leaflet

(x1)

4.5

Guarantee envelope pack

(x1)

4.6

Magnetic lighting instruction label

(x1)

4.7

Gas conversion label

(x1)

7.2

Recommendations before installing

7.2.1

Domestic hot water circuit design

Water pressure

The minimum working pressure to obtain the maximum

domestic flow is 1,0 bar.

The maximum working pressure of the domestic hot water

circuit is 10 bar. If the cold water supply pressure exceeds this,

then a pressure-reducing valve must be fitted in the supply to

the boiler.

‘Hard’ water areas

The temperatures within the heat exchanger are limited by the

boiler control system to minimise scale formation within the hot

water pipework. However, in areas where the water is ‘hard’ (i.e.

more than 200 mg/L of calcium carbonate), it is recommended

that the hot water setting is reduced and that a scale reducer

is fitted, refer to the manufacturer’s instructions or consult the

local water company for additional advice.

Domestic water flow rate

The domestic hot water flow has a restrictor, factory fitted,

which reduces the flow to a maximum of:

- 24cxi

8 l/min,

- 30cxi

10 l/min,

- 35cxi

12 l/min.

INSTALLATION