Interlogix NX-1710E User Manual
Page 13
NX-1710E Single Door Control
13
Segment 5
LED2 (Red) Options:
LED1 -
"On" to follow Armed status of system. (Default is “On”)
LED2 -
"On" to toggle with the relay activation.
LED3 -
"On" if inverted.
LED4–8
Reserved.
Segments 6 – 8 Reserved
L
OCATION
2 P
ROGRAMMING THE
X-10 A
DDRESS FOR THE
S
CAN
F
UNCTIONS
(6 segments of numerical data)
Segment 1
Module Number
Program a number from 0 -15 to represent the corresponding X-10 Module Number from the following table.
Default is 0.
Module
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Seg 1
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Segment 2
House Code
Program a number from 0-15 to represent the corresponding X-10 House code from the following table. Default
is 0.
X-10 ADDRESS CODES
0=A
4=E 8=I 12=M
1=B 5=F 9=J 13=N
2=C 6=G 10=K
14=O
3=D 7=H 11=L 15=P
Segment 3
Reader “A” Single Scan Function
Program the X-10 function that is performed when a card is scanned {one beep} at Reader “A”. This location
only needs to be programmed if Location 0, Segment 1, Option 7 is set. Use the following table. Default is 2.
Function #
Function performed
Function #
Function performed
0 All
units
off 4
Dim
1
All lights on
5
Bright
2 On 6
All lights off
3 Off
All
others
Reserved
Segment 4
Reader “A” Triple Scan Function
Program the X-10 function that is performed when a card is scanned three times {three beeps} at Reader “A”.
The descriptions of the function codes are the same as for Single Beep Scan Function. This location only needs
to be programmed if Location 0, Segment 2, Option 7 is set. Use the above table. Default is 3.
Segment 5
Reader “B” Single Scan Function
Program the X-10 function that is performed when a card is scanned {one beep} at Reader “B”. This location
only needs to be programmed if Location 0, Segment 1, Option 7 is set. Use the following table. Default is 2.
Segment 6
Reader “B” Triple Scan Function
Program the X-10 function that is performed when a card is scanned three times {three beeps} at Reader “B”.
The descriptions of the function codes are the same as for Single Beep Scan Function. This location only needs
to be programmed if Location 0, Segment 2, Option 7 is set. Use the above table. Default is 3.