4 message communication 3-37 – KEYENCE DL-EP1 User Manual
Page 67
3-4 Message Communication
3-37
3
C
om
m
uni
ca
tin
g
w
ith
the
G
T2
S
er
ies
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -
Attributes for GT2 Series (Common to all GT2 Series)
Designate the ID number (01H to 0FH) of a sensor amplifier as the instance ID.
Class
Attribute
ID
Name
Description
Attribute
Data
Type
Group1
0320H
(800)
Group1
Entry count
Indicates the number of items (entries) that can
be set in Group 1.
Parameter range: 9
R
DINT
0321H
(801)
Sensor
amplifier
error state
Indicates the error status of the sensor amplifier.
bit0: Overcurrent error (ErC)
bit1: Head error (ErH)
bit2: EEPROM error (ErE)
bit3: Jam check error (Er.chK)
bit4: Self-timing delay (Er.dLY)
bit5: Number-of-units error (Er.Unit)
bit6: Calculation error(Er.CAL)
bit7: Calculation-only mode error (Er.noH)
R
DWORD
0322H
(802) to
0323H
(803)
Reserved for system
0324H
(804)
Control
output
Indicates the control output status.
Parameter range: 00H to 1FH (initial value: 00H)
bit0: HIGH output
bit1: LOW output
bit2: GO output
bit3: HH output
*1
bit4: LL output
*1
R
DWORD
0325H
(805)
Comparator
value (P.V.
Value)
*2, *3, *4
Indicates the comparator value (P.V. value).
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R
DINT
0326H
(806)
Raw value
(R.V. Value)
*2, *4, *5
Indicates the raw value (R.V. value).
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R
DINT
0327H
(807)
Peak value
during
sampling
*2 , *3, *4, *6
Indicates the peak-hold value in peak-to-peak
mode.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R
DINT
0328H
(808)
Bottom value
during
sampling
*2, *3, *4, *6
Indicates the bottom-hold value in peak-to-peak
mode.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R
DINT
0329H
(809)
Calculation
display
value
*2, *4, *7
Indicates the calculation display value.
Parameter range:
-199.9999 to 199.9999 (initial value: 0.0000)
R
DINT