Attributes
Instance
ID
Attribute
ID
Name
Description
Attribute
Data
Type
00H
64H
(100)
Status
Indicates the status of this unit and connected
sensor amplifier.
Bit 0: DL-EP1 Error Status
Bit 1 to bit 13: Reserved for system
Bit14: Warning Status
Bit15: Error Status
R
WORD
65H
(101)
Sensor Error
Status
Indicates the error status of the connected
sensor amplifiers. If an error occurs, the bit of the
corresponding ID number of amplifier is turned
to ON.
Bit 0 to bit 14: ID number 1 to ID number 15
Bit15: Reserved for system
R
WORD
66H
(102)
Warning
Status
(Unassigned)
R
WORD
67H
(103)
Reserved for system
68H
(104)
Current
Value 0
Property
Indicates the status of current value 0 of each
amplifier. If the current value 0 is “Over Range",
“Under Range", or "Invalid", the bit
corresponding to the ID number is turned ON.
Bit 0 to bit 14: ID number 1 to ID number 15
Bit15: Reserved for system
R
WORD
69H
(105)
Current
Value 1
Property
Indicates the status of current value 1 of each
amplifier. If the current value 1 is "0ver Range",
"Under Range", or "Invalid", the bit
corresponding to the ID number is turned ON.
Bit 0 to bit 14: ID number 1 to ID number 15
Bit15: Reserved for system
R
WORD
6AH
(106) to
6BH
(107)
Reserved for system
6CH
(108)
Error ID
Number
Indicates the ID number of the unit having error.
Parameter range: 0 to 15 (initial value: 0)
R
UINT
6DH
(109)
Error Code
Indicates the error code that is happening.
Parameter range: 0 to 65535 (initial value: 0)
R
UINT
6EH
(110)
Warning ID
Number
(Unassigned)
R
UINT
6FH
(111)
Warning
Code
(Unassigned)
R
UINT