3 cyclic communication 3-10 – KEYENCE DL-EP1 User Manual
Page 40
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (GT2) -
3-3 Cyclic communication
3-10
3
C
om
m
uni
ca
tin
g
w
ith
the
G
T2
S
er
ies
Output 5
(LL)
26
ID08
. . . . .
ID01
27
Reserved for
system
ID15
. . . . .
ID09
External
Input
Response 1
(Preset)
28
ID08
. . . . .
ID01
29
Reserved for
system
ID15
. . . . .
ID09
External
Input
Response 2
(Timing)
30
ID08
. . . . .
ID01
31
Reserved for
system
ID15
. . . . .
ID09
External
Input
Response 3
(Preset)
32
ID08
. . . . .
ID01
33
Reserved for
system
ID15
. . . . .
ID09
External
Input
Response 4
(Error
Clear)
34
ID08
. . . . .
ID01
35
Reserved for
system
ID15
. . . . .
ID09
External
Input
Response 5
(Unassigned)
36
ID08
. . . . .
ID01
37
Reserved for
system
ID15
. . . . .
ID09
Error
ID Number
40
Current Error ID Number (16-bit unsigned integer)
41
Error
Code
42
Current Error Code (16-bit unsigned integer)
43
Warning
ID Number
44
Current Warning ID Number (16-bit unsigned integer)
45
Warning
Code
46
Current Warning Code (16-bit unsigned integer)
47
Current
Value 0
(Comparator
Value (P.V.)
or Raw
Value (R.V.))
48
ID Number 1 (Current Value 0) (32-bit signed integer)
49
50
51
:
:
104
ID Number 15 (Current Value 0) (32-bit signed integer)
105
106
107
Current
Value 1
(Unassigned)
108
ID Number 1 (Current Value 1) (32-bit signed integer)
109
110
111
:
:
164
ID Number 15 (Current Value 1) (32-bit signed integer)
165
166
167
Name
Address
(Byte)
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0