Appendix a – Inovonics FA104 User Manual
Page 15

© 1994 INOVONICS Corporation
11
LIT-FA104-USER 14-Nov-95
Appendix A
FA416 Receiver Parameters
Default
Active
on
Output Condition Programmable Options
1
Alarm
ALARM / ALARM+TAMPER / TAMPER /
2
Alarm
LO BATT / INACTIVE / TAMP+LO BATT /
3
Alarm
TAMP+INACTIVE / LO BATT+INACTIVE /
4
Alarm
ANY TX FAULT / DISABLED
Transmitter Default
Condition Mode
Alarm
Follower
FOLLOWER / MOMENTARY / LATCHING
Inactive
Follower
Tamper
Latching
Low
Batt
Latching
Default Momentary Output time: 4 seconds
1 - 16 seconds
Default Receiver Parameters:
System ID:
(randomly assigned at factory)
0 - 255
Point
supervision:
Yes
Yes / No
Supervision window:
4 hours
1 - 99 minutes, 1 - 99 hours
Access code:
3446
0000 - 9999
Vision Plus compatible:
No
Yes / No
To reset a receiver to default parameters refer to Page 5 or see the receiver user manual.
Default Transmitter Parameters
Point # Contact Output Check-in
1
N/O 1
60
SEC
2
N/O 2
60
SEC
3
N/C 3
60
SEC
4
N/C 4
60
SEC
5
N/O 1
60
SEC
6
N/O 2
60
SEC
7
N/O 3
60
SEC
8
N/O 4
60
SEC
9
N/C 1
60
SEC
10
N/C 2
60
SEC
11
N/C 3
60
SEC
12
N/C 4
60
SEC
13
N/C 1
60
SEC
14
N/C 2
60
SEC
15
N/C 3
60
SEC
16
N/O 4
NONE
Note: Point 16 in Table 1 is programmed with no check-in. This configuration is often desirable for use with the
FA204 Pendant, permitting the pendant to be taken out of range without being reported inactive.