6
3.1.1 & 3.1.2 CONFIGURE SERIAL PORT 1 and PORT 2
Activate the CONFIGURE menu and press the ENTER key when the DT210 displays 'CONFIG
SER PORT1'.
The DT210 prompts: "BAUD = NNNN"
where NNNN = the current baud rate selection. The baud rate menu selections are:
"BAUD = 300" - selects 300 baud.
"BAUD = 600" - selects 600 baud.
"BAUD = 1200"- selects 1200 baud.
"BAUD = 2400"- selects 2400 baud.
"BAUD = 4800"- selects 4800 baud.
"BAUD = 9600"- selects 9600 baud.
Press the CONTINUE key to scan the baud rate selections . Press the ENTER key to complete
the baud rate selection.
The DT210 prompts: "N DATA N STOP"
where N DATA = number of data bits per character, N STOP = number of stop bits per
character.
The character format menu selections are:
"8 DATA 1 STOP"
"8 DATA 2 STOP"
"8 DAT PAR 1 STOP"
"8 DAT PAR 2 STOP"
"7 DATA 1 STOP"
"7 DATA 2 STOP"
"7 DAT PAR 1 STOP"
"7 DAT PAR 2 STOP"
Press the CONTINUE key to scan the character format selections.
Press the ENTER key to complete the character format selection.
If a data format was chosen that had "PAR" then the DT210 with the parity menu:
"PARITY ODD"
"PARITY EVEN"
Press the CONTINUE key to scan the parity selections.
Press the ENTER key to complete the parity selection.
NOTE : Do the same for PORT 2.