Industrial Data Systems IDS DT200 User Manual
Page 22

20
4.2.6 PRINT
The PRINT key is used to send the weight, time, and date to the printer. Press the PRINT key.
The DT210 prompts: 'PRINT SCALE WT'.
Press the ENTER key to print the weight.
4.2.7 PAPER FEED
The PAPER FEED key is used to send line feed characters to the printer.
4.2.8 DECIMAL POINT
The DECIMAL POINT key is used to enter the decimal point for numeric data.
4.3 SCALE INTERFACE
The SCALE INTERFACE permits the DT210 to be used in a wide range of weighing
applications. The weigh meter interface is connected to the DT210's serial channel 1 input.
Channel 1 can accept 2 types of input: RS232 or CURRENT LOOP.
The DT210 uses the weight from the scale for:
1. Display the weight on the scale.
2. Display the calculated net weight.
3. For calculating, printing, and storing weigh transactions.
The DT210 monitors the status of the scale and displays the status in the following form:
-- Scale data valid.
-M-
-- Scale in motion.
OVR
-- Scale overload.
NEG.
-- Weight below 0.
-I-
-- Scale status = inhibit.
-U-
-- Received units differ from configured units.
-G-
-- Scale not in gross mode.
CBY
-- Count-by error.