Synchronization


The sequencer can be synchronized to an external clock using MIDI in or
Sync In.


Midi Clock to Sync Out

If the synchronization switch is in the MIDI-in position, the Miami’s sequencer
will be slaved to the MIDI Clock of a MIDI Master connected to the MIDI-in
port.

A Sync-out Signal will be generated at the Sync socket for other devices that
have a Sync-In socket.


Sync Slave:

If the synchronization switch is in the Sync-In Position, the Miami’s sequencer
will be slaved to the Sync Clock of an external Sync-Master connected to the
Sync socket.

Sync Master:

If the synchronization switch is in the Sync-Out Position, the Miami functions
as a Sync Master.
A Sync-out Signal will be generated at the Sync socket for other devices that
have a Sync-In socket.

You can adjust the tempo with the Tempo Knob, and the Start/Stop
button will start or stop the sequencer.