Synchronization – acidlab Miami User Manual
Page 20

20
Synchronization
 
 
The sequencer can be synchronized to an external clock using MIDI in or 
Sync In. 
 
 
Midi Clock to Sync Out
If the synchronization switch is in the MIDI-in position, the Miami’s sequencer 
will be slaved to the MIDI Clock of a MIDI Master connected to the MIDI-in 
port. 
A Sync-out Signal will be generated at the Sync socket for other devices that 
have a Sync-In socket. 
 
 
Sync Slave:
If the synchronization switch is in the Sync-In Position, the Miami’s sequencer 
will be slaved to the Sync Clock of an external Sync-Master connected to the 
Sync socket. 
 
 
Sync Master:
If the synchronization switch is in the Sync-Out Position, the Miami functions 
as a Sync Master. 
A Sync-out Signal will be generated at the Sync socket for other devices that 
have a Sync-In socket. 
You can adjust the tempo with the Tempo Knob, and the Start/Stop 
button will start or stop the sequencer. 
 