MODEL NUMBER NOMENCLATURE

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17

5 8 0 J E 0 6 A 0 7 2 A 1 A 0 A A

____________

______

________

______

Unit Type

Packaging

580J = Cooling/Gas Heat RTU

A = Standard

Legacy Series w/Puron Refrigerant

B = LTL

Voltage

Factory Installed Options

E = 460---3---60

0A = None

J = 208/230---1---60
P = 208/230---3---60

Intake/Exhaust Options

T = 575---3---60

A = None
B = Temp econo w/ baro relief

Cooling Tons

E = Temp econo w/ baro relief & CO

2

04 = 3 Ton

H = Enthalpy econo w/ baro relief

05 = 4 Ton

L = Enthalpy econo w/ baro relief & CO

2

06 = 5 Ton

Q = Motorized 2 pos damper

07 = 6 Ton
08 = 7.5 Ton

Indoor Fan Options

09 = 8.5 Ton

1 = Standard static option

12 = 10 Ton

2 = Medium static option

14 = 12.5 Ton

3 = High static option

Refrig. System/Gas Heat Options

Coil Options

A = Standard 1---Stage Cooling models/Nat gas heat

Models w/Round Tube Plate Fin (RTPF) condenser coil

B = Standard 1---Stage Cooling models/Low NO

x

heat

(Outdoor --- Indoor --- Hail Guard)

C = Standard 1---Stage Cooling models/SS HX

A = Al/Cu ---Al/Cu

D = 2---Stage Cooling models 08---14

B = Precoat Al/Cu --- Al/Cu

F = 2---Stage Cooling models and SS HX

C = E---coat Al/Cu --- Al/Cu

G = 1---Stage Cooling/Al HX w/Perfect Humidity 04---07

D = E---coat Al/Cu --- E---coat Al/Cu

H = 1---Stage Cooling/Low NO

x

w/Perfect Humidity 04---07

E = Cu/Cu --- Al/Cu

J = 1---Stage Cooling/SS HX w/Perfect Humidity 04---07

F = Cu/Cu --- Cu/Cu

K = 2---Stage Cooling/Al Gas HX w/Perfect Humidity 08-14

M = Al/Cu --- Al/Cu --- Louvered Hail guards

M = 2---Stage Cool/SS Gas HX w/Perfect Humidity 08-14

N = Precoat Al/Cu --- Al/Cu --- Louvered Hail Guards
P = E coat Al/Cu --- Al/Cu --- Louvered Hail Guards

Heat Level

Q = E coat Al/Cu --- E coat Al/Cu --- Louvered Hail Guards

Standard/Stainless Steel

R = Cu/Cu --- Al/Cu --- Louvered Hail Guards

072 = 72,000

S = Cu/Cu --- Cu/Cu --- Louvered Hail Guards

115 = 115,000

Models w/All aluminum, Novation condenser coils

125 = 125,000

(Outdoor --- Indoor --- Hail Guard)

150 = 150,000

G = Al/Al --- Al/ Cu

180 = 180,000

H = Al/Al --- Cu/Cu

224 = 224,000

J = Al/Al --- E coat Al/Cu

250 = 250,000

K = E coat Al/Al --- Al/ Cu

Low NO

x

L = E coat Al/Al --- E coat Al/Cu

060 = 60,000

T = Al/Al --- Al/Cu --- Louvered Hail Guards

090 = 90,000

U = Al/Al --- Cu/ Cu, Louvered Hail Guards

120 = 120,000

V = Al/Al --- E coat Al/Cu, Louvered Hail Guards
W = E coat Al/Al --- Al/ Cu, Louvered Hail Guards
X = E coat Al/Al --- E coat Al/Cu, Louvered Hail Guards