E5 series, Elreha, Elec tric al cir cuit s – Merrychef eikon e5 User Manual
Page 49: E5 7
Service & Parts Manual original Instructions
Part Number 32Z3814 US
Issue 1
49
1
2
3
4
5
6
7
8
A
B
C
D
8
7
6
5
4
3
2
1
D
C
B
A
1
14
e5 series
e5
7
23-Aug-2010
C:\Users\ha\ELREHA\Projects\Manitowoc\Merrychef eikon ovens\Wiringloom\wireingloom - Copy.ddb - Documents\e5.Sch
Title:
Size:
PCB No.:
Date:
File:
Drawing No.:
Sheet
of
A2
ELREHA
Elektronische Regelungen GmbH
Drawn by:
H.Wirth
29
11
Heater 1.6kW
58
59
64
65
Convection fan
60
61
M
Stirrer motor
78
78
77
77
Heater 1.6kW
blue
black
brown
blue
brown
COOLING FAN
blue
black
brown
blue
brown
F5
32
30
31
33
34
T2
MW2
Diodboard
41
43
42
F4
46
45
44
47
48
T1
MW1
Diodboard
55
57
56
MW1 left hand side (From the front)
MW1 right hand side (From the front)
230
230
F5
32
30
31
37
38
33
K2
35
36
34
T2
MW2
Diodboard
41
43
42
F4
46
45
44
51
52
47
K1
49
50
48
T1
MW1
Diodboard
55
57
56
208
240
240
208
60Hz
50Hz
Aux
Power
Heater Supply
M.W. Supply
Neutral In
Interblock
Switch
Connector
24VAC
Supply
On/Off
Air filter
Overheat Cavity
Cooling Fan
Magnetron stirrer motor 1
Heater Supply out
MW2
MW1
Neutral MW2
Interlock Switches
Temperature Input
P/C - Bus
C - Bus
P - Bus
RJ-45
RJ-12
RJ-11
RPM Input
13
24
15
17
16
14
18
19
21
20
22
23
31
45
Neutral MW1
25
26
10
29
30
44
58
59
60
61
69
70
71
72
73
74
Overheat MW1
Overheat MW2
+
-
SRB Transformer
NC
NC
MW 1
51
52
Voltage selection relay
37
38
MW2
Delta
L3
L2
L1
Star
F1
7
8
9
F2
F3
4
1
5
2
6
3
15
14
13
12
11
10
6
4
3
2
1
18
19
16
17
25
26
On/Off
Air filter
Cavity
69
70
Cavity
71
72
MW1
8
5
1
2
PRI
TR3
Heater
Microwave
Control
+
-
For Dual phase or
3 phase Delta ovens
Wire No's 4 & 6
connect to L1/L2
Wire No 5
L2
L1
N
For single phase ovens
Wire No's 4,5 & 6
connect to L1/L2
5
5
20
22
21
12
Right Hand Side Switch assly
23
24
Left Hand Side Switch assly
SW2 Secondary
C
NC
NO
SW1 Monitor
C
NC
NO
SW3 Primary
C
NC
NO
Note
Switches Shown in
Door Closed position!
Convection Fan
64
65
73
74
MW2
MW1 left hand side (From the front)
MW1 right hand side (From the front)
BTS
Coms modules
X2.1
X2.2
X4a
1
2
X4b
X4a
X2.1
Voltage selection
Voltage-selection-Relay-driver.Sch
Relays driver
1
2
3
4
X101
1
2
3
X102b
X102a
X102(N)
Common Connector block
interlock switches
1
2
3
X10
Power supply
Power-supply.Sch
1
2
X1
12V;5V;3.3V
12V
5V
Thermocoupler input
Thermocoupler-input.Sch
1
2
X14
X2.2
C/B Bus
C-P-Bus.Sch
C-Bus
C-P-Bus.Sch
P-Bus
C-P-Bus.Sch
Safety relay Supply
Safety-relay.Sch
Air filter feedback
feedback.Sch
+12V
X18e.2
X18a.2
X18b.2
X1.1
X1.2
MCU
MCU.Sch
8
4
6
X11
X12
X13
Power switch feedback
( Heater & M.W. only)
Motor feedback
feedback.Sch
1
2
3
X5
1
2
X18b
1
2
X18c
1
2
X18d
1
2
X18e
1
2
3
X18a
Safety Relay Heater
Safety-relay.Sch
Triac 16A output
Triac-output.Sch
Safety Relay M.W.
Safety-relay.Sch
Current Sense
Current-Sense.Sch
Hybrid Relay 1
Hybrid-Relay.Sch
Door switch
door-switch-detection.Sch
Lcs_Heater
Lcs_MW
L'cs_MW
Safety Relay Aux
Safety-relay.Sch
Line voltage monitoring
Line-voltage-monitoring.Sch
L
N
1
2
X103
Triac 1A output
Triac-output.Sch
Triac 2A output
Triac-output.Sch
Triac 1A output
Triac-output.Sch
1
2
X9
L'
N
Convection Fan
0-10V-out.Sch
0...10V passiv
isolated output
1
2
3
X3
1
2
X8
1
2
X17
1
2
3
4
X20
X8.1
N
X17.1
N
X20.1
N
1
2
X103.1
L
N
Hybrid Relay 2
Hybrid-Relay.Sch
ELEC
TRIC
AL
CIR
CUIT
S