AVerMedia Technologies EB1304 User Manual
Page 23
19
OSD MENU
Description
2006 / 12 / 11
17 : 54 : 50
ON
ON
ON
OFF
NO
SUBMENU
PASSWORD CHANGE
VIDEO ADJUSTMENT
DATE
TIME
AUTO RECORD
AUTO SCAN
PASSWORD SETUP
AUDIO RECORD
AUDIO MUTE
NTSC
ON
VIDEO SYSTEM
TEMERATURE SET
BUZZER
TEMPERATURE SET:
Set the DVR unit temperature type and high/low
threshold limit.
040
050
005
050
TEMPERATURE SET
TEMPERATURE TYPE
HIGH THRESHOLD
LOW THRESHOLD
DVR HOT PROTECT
DVR COLD PROTECT
CENTIGRADE
TEMPERATURE TYPE:
Temperature pattern display on front LED panel.
HIGH THRESHOLD:
Set a specific temperature limited for fan active. When
the hard disk temperature is higher than limited
temperature, the fan will be active. The default value is
50
°C.
LOW THRESHOLD:
Set a specific temperature limited for fan stop. When
the hard disk temperature is lower than limited
temperature, the fan will be stop. The default value is
45
°C.
DVR HOT PROTECT:
Set the temperature limit to shutdown hard disk when
the DVR unit temperature is higher than (>) limited. The
default value is 60
°C.
DVR COLD PROTECT:
Set the temperature limit to stop recording when the
DVR unit temperature is lower than (<) limited. The
default value is 5
°C.
BUZZER:
Enable/disable system buzzer sound. The default
setting is ON.
Status
Sound
System Power ON
One long buzz sound
Video Loss
Continue long buzz sound
Fan stop/broken
Continue short buzz sound
Hard Disk is Full
Three Long buzz sound