Command ‘s’ - get setup mode header, Command ‘s’ – exit setup mode – Innovate Motorsports OT-2 SDK User Manual
Page 23
23
Command ‘S’ - Get Setup Mode Header
Sent:
1 byte
{
U8 Cmd;
// ‘S’
}
Responds:
15 bytes
{
U8 VersionH;
// Firmware version MSB
U8 VersionL;
// Firmware version LSB
U8 Identifier[4]; // Unique identifier
U8 Reserved[9];
// Don’t ask!
}
Notes:
This is exactly the same response you receive automatically
when you entered the mode.
Command ‘s’ – Exit Setup Mode
Sent:
1 byte
{
U8 Cmd;
// ‘s’
}
Responds:
None
Notes:
This command returns you to in-band mode, and disables the
watchdog timer.
See also other documents in the category Innovate Motorsports Measuring instruments:
- LogWorks 3 (145 pages)
- MTX-D, Water Temperature/Volt Gauge (10 pages)
- MTX-D, Oil Temperature/Pressure Gauge (10 pages)
- MTX-D, EGT Gauge (10 pages)
- MTX-D, Boost/Shift Gauge (12 pages)
- MTX-L (16 pages)
- LC-2 (12 pages)
- LM-2 (50 pages)
- DB Digital Air/Fuel Gauge (1 page)
- TC-4 (11 pages)
- SSI-4 (16 pages)
- DL-32 (30 pages)
- Autronic Output Cable (1 page)
- Analog Display (1 page)
- ST-12 (33 pages)
- LC-1 (24 pages)
- XD-16 (18 pages)
- LMA-3 (30 pages)
- LM-1 RPM Converter (Aux. Input Cable 2) (9 pages)
- LM-1 Digital Air/Fuel Ratio (Lambda) Meter (26 pages)
- PL-1 (9 pages)
- SCG-1 (19 pages)
- OT-2 (26 pages)
- OT-1 (29 pages)
- RAD-1 (1 page)
- G3 Air/Fuel Gauge Manual (four connector model) (2 pages)
- G3 Air/Fuel Gauge Manual (single connector model) (1 page)
- G2/G4/G5 Air/Fuel Gauge Manual (four connector model) (2 pages)
- G2/G4/G5 Air/Fuel Gauge Manual (single connector model) (1 page)
- LM-2 Quick Start Guide (2 pages)
- MTX-L Quick Start Guide (2 pages)
- LM-1 Quick Start Guide (2 pages)
- LC-1 Quick Start Guide (2 pages)
- XD-16 Quick Start Guide (2 pages)
- Standalone Gauge Kit Quick Start Guide (2 pages)
- OT-2 Quick Start Guide (2 pages)
- DL-32 Quick Start Guide (2 pages)