Hired-Hand RollSeal Rolling Dampers User Manual
Page 4
RollSeal, INC.
• 1751 Co Road 68 • Bremen, Alabama 35033 • Phone 256-287-7000 • Fax 256-287-7010
Sheet No. 4801-0158 Rev 4-04
Page 4 of 5
7.
Connect cord from rolling damper to controller as shown in diagram below. Match wire colors to colors on terminal block label.
7.
The RollSeal has a switch on the control box that allows the curtain to operate automatically or manually. When the RollSeal is
mounted and power is installed, check the operation of the RollSeal by pressing the switch to "OPEN". The curtain should open
to within one to three inches from the top. Place the switch in the "AUTOMATIC" position, and the curtain should return to the
closed position, touching the frame at the bottom. If all checks well, your RollSeal is now ready for use and should be placed in
the "AUTOMATIC" position for normal operation.
8. Installation
complete.
NOTICE
The Shutter Operation
Circuitry Requires
Constant Power Separate
From Fan Power.
NOTE: To install cord to controller, match
wire color to terminal block label.
PCB Board
Transformer
L1 Black
120 VAC L2 White
230 VAC L2 Orange
Fan Power
To Constant Power
NOTICE
May be controller operated.
L1
GND
L2
115 Volt Constant Power (Wires
Off Transformer)
Use white and black wires for connection.
Orange is not used. Taper or wire nut off.
230 Volt Constant Power (Wires
Off Transformer)
Use orange and black wires for connection.
White wire is not used. Tape or wire off.
Connecting From 115 Volt Fan
Connect in parallel, 115 volt and RET on PCB
board to the fan's power source.
Connecting From 230 Volt Fan
Connect, in parallel, 230 volt and RET on PCB
board to the fan's power source.