6 serial port 6 configuration – IEI Integration PPC-5152-D525 v2.10 User Manual
Page 94
PPC-5152-D525 Falt-bezel Panel PC
Page 80
Î
IO=3E8h;
IRQ=3, 4,
5, 6, 7, 10,
11, 12
Serial Port I/O port address is 3E8h and the interrupt
address is IRQ3, 4, 5, 6, 7, 10, 11, 12
Î
IO=2E8h;
IRQ=3, 4,
5, 6, 7, 10,
11, 12
Serial Port I/O port address is 2E8h and the interrupt
address is IRQ3, 4, 5, 6, 7, 10, 11, 12
Î
IO=2E0h;
IRQ=3, 4,
5, 6, 7, 10,
11, 12
Serial Port I/O port address is 2E0h and the interrupt
address is IRQ3, 4, 5, 6, 7, 10, 11, 12
Î
Serial Port 5 Mode [RS422/485]
The Serial Port 5 Mode option is set the Serial Port 5 signaling mode to RS-422/485 and
can not be changed.
5.3.5.1.6 Serial Port 6 Configuration
Î
Serial Port [Enabled]
Use the Serial Port option to enable or disable the serial port.
Î
Disabled
Disable the serial port
Î
Enabled D
EFAULT
Enable the serial port
Î
Change Settings [Auto]
Use the Change Settings option to change the serial port IO port address and interrupt
address.
Î
Auto D
EFAULT
The serial port IO port address and interrupt address
are automatically detected.