Testing with the remote control, Service side – manual leak down test, Service side activation via remote – IPA Tools 9008-DL Super MUTT Deluxe Edition User Manual
Page 22
22
SERVICE SIDE – MANUAL LEAK DOWN TEST
1. Press Air Control rocker Switch to the right Service position
(located on upper panel).
Turn power switch to desired the power source.
2. Turn the Service Side (blue) ball valve (fig. 7-E) to the Open position.
3. Once the Service Side (fig. 7-F) gauge reflects the desired pressure, then turn
the ball valve to the Closed position to begin leak down test.
4. Note any PSI drop after stabilization of pressure.
5. Look for air loss according to your local code or test by noting consistent air
drop over time. If air pressure continues to drop, you can turn air supply back
on the Service Side (fig. 7-E) and begin to look for the leak by inspecting air
system if an unacceptable air pressure loss is observed.
TESTING WITH THE REMOTE CONTROL
The remote control can be used to cycle air on and off to the Service Side by
depressing the small button on the remote control.
The remote control allows a technician to operate the Service Side air and
actuate the brakes thereby allowing the inspection and service of the air brake
System. When operating the Service Side via remote, the Emergency Side must
be precharged with the ball valve in the Open position. If the Emergency Side
has insufficient pressure, the Service Side brakes will not actuate.
WARNING: Remember to sufficiently chock/block the wheels of the trailer
before operation to prevent the trailer from rolling. Trailers should always
be parked on a flat/level surface before testing. Before using the remote,
please be aware that trailer brake parts and components can explode, dis-
lodge or become damaged when air pressure is introduced to the system.
For the safety of the user and others in the vicinity, extreme caution should
be used to avoid injury or death. Do not put yourself in harm’s way.
SERVICE SIDE ACTIVATION VIA REMOTE
• Push red air control switch to the Emergency Side position.
• Turn Emergency Side valve to the Open position.
• Charge Emergency Side with desired air pressure.
• Turn Service Side valve to the Open position.
• Move red air control switch to Remote position (The smaller button
on the wireless remote controls the air flow when pressed).
• Point the remote in the general direction of the MUTT
®
(Install antenna for improved range).
• Press small button once to engage the service air brakes.
• Press small button again to disengage the brakes.
• Repeat as necessary.