TOP OPERATION ERRORS
Not using the flame observation view port on the side of the heater to VISUALLY
SET THE FLAME. (See page 26AA of the owner’s manual)
Over firing the heater by using incorrect oil and air pressures. VISUALLY SET
THE FLAME see page 26 AA in owner’s manual. Flame tips should be no more
than 3/4 of the way into the combustion chamber.
Not using proper fuel management with the waste oil fuel. Pre-straining all fuels
and draining water form the tank weekly. (See the owner’s manual)
Using non-recommended fuels. (See the owner’s manual)
Not checking the barometric damper setting for the venting of exhaust gases.
(See the owner’s manual)
Failure to clean the heat exchanger/combustion chamber. (See owner’s manual
Section 20)
Failure to clean and maintain the burner. (See owner’s manual)