Lanair HI320 User Manual
Page 6
SECTION 3 HEATER INSTALLATION
3.1 Do not install the heater on a combustible surface of any kind.
3.2 Install the heater in a location to utilize total heat throw.
3.3 Install the heater in a location to permit a correct outdoor chimney exit to
eliminate down drafts, and provide easy chimney installation and
maintenance.
3.4 Install the heater in a location to permit the fuel supply to be as close as
possible.
3.5 Do not install the heater more than 10 feet above the top of the fuel supply
tank.
3.6 Before suspending the heater check the supporting structure and reinforce
if necessary to support the weight of the heater/system. Refer to Section
2.2.
3.7 Minimum Clearance to combustibles
Top
6”
Chimney Connector
18”
Sides
18”
Rear
18”
Front
24”
Bottom
18”
3.8 Use 3/8” steel threaded rod to suspend the heater from a capable load
carrying ceiling structure when not using the Lanair® Waste Oil Storage
Tank.
3.9 The heater must be suspended level for proper operation. A heater that is
installed not level could cause a hazardous situation in which personal
injury or property damage may result.
3.10 Installation Diagram (See page 6A).