Biamp TEC-1 User Manual
Page 13
![background image](/manuals/329631/13/background.png)
13
TEC-1 INSTALLATION
Connect the wire according to the color code silkscreened as text next to the IDC or as shown on the label
on the back enclosure (see figure below). The color code uses the T568A standard for wiring. When using the
T568B wiring scheme, please note that the orange wire pair (OR and WH/OR) and green wire pair (GR and
WH/GR) need to be swapped. After inserting the wires, press the tabs until the insulation is punctured with an
audible click. No wire stripping is necessary.
IDC wiring scheme
Note the appropriate bend radius requirements for category cables as shown in the figure below.
Software support in Tesira configuration software Version 1.1 or later provides user programming of all remote
functions, network setup, device naming, and device maintenance.
Visit www.biamp.com to obtain firmware and software updates related to this product. To speak with an
Applications Engineer, please call 1.503.641.7287 or email [email protected].
Insulation Displacement Connector (IDC)