Basic parameters and commands

Pearleye Technical Manual V2.3.0

43

Electromechanical shutter (I)

The Pearleye P-007 LWIR / Pearleye P-030 LWIR models are equipped with an
electromechanical shutter that can be controlled with the command

I.

Use

I=1 to close and I=0 to open the shutter.

Temperature warning (T)

The command

T=1 displays the content of the temperature warning register.

The lowest order bit has the same function as LED L3 placed at the backside of
the camera housing. If the value 1 is output, the temperature of the microbo-
lometer sensor is outside the optimum range. After switching on the camera you
have to wait some time until the set value is reached. If the temperature warn-
ing remains active for a longer period, the environment temperature of the
camera should be checked.

The camera is equipped with an internal temperature sensor. The temperature
can be displayed using the command

T=2. The temperature is output as 16-bit

value. The 4 most significant bits contain information about the temperature
sensing state. The remaining 12 bits contain two’s complement of 1/16 degrees
Celsius.

Note

The shutter is open by default (power off).

The typical life time of the electromechanical shutter is:
1 million control cycles.

GigE feature name (CameraSpecialFeatures)

Feature Visibility Description

MechanicalShutter

Beginner

Set the electromechanical
shutter state manually.

(I= command)

Table 15: GigE feature: Electromechanical shutter

Note

For information about the starting procedure see

Warm-up

period

on page 11.